Repair

Troubleshooting an Ampeg valve amplifier

What each symptom usually means, in the order it is worth checking, and an honest note about which faults you should not attempt yourself.

Read the safety guide first

Valve amplifiers store lethal voltages after they are switched off and unplugged. Do not open the chassis of an amplifier until you have read the safety guide. Everything below is organised around what can be established from the outside first.

Start with the obvious

Most “broken” amplifiers are not broken. Before assuming the worst, confirm the following:

  • The amplifier is plugged into a socket that actually works.
  • The mains fuse is intact and of the correct rating. Do not fit a larger fuse.
  • The speaker cabinet is connected, with the correct impedance, and the speaker cable itself is sound. A cable that has failed internally causes exactly the symptoms of a dead output stage.
  • The standby switch is in the operate position.
  • The volume and tone controls are not turned fully down, and the instrument cable is not the faulty item. Try a different cable and a different instrument before opening anything.
  • If there is a footswitch, the tremolo or reverb is not simply switched off.

Symptom by symptom

No sound at all, and no valves glowing

The most likely cause is the mains fuse or the mains supply.

  • Check that the fuse has not blown. If it has, replace it once with one of the rating printed on the chassis, and if it blows again, stop — there is a fault that a larger fuse will not fix.
  • If the fuse is intact, check the mains lead and the socket, and check the mains switch with a meter.
  • If the fuse blows immediately on power-up, the likely causes are a failed rectifier, a shorted filter capacitor or a shorted mains transformer. All three require a technician.
Valves glow but there is no sound

Suspect the speaker circuit, the output stage, or the high-voltage supply.

  • Confirm the speaker and its cable with a meter. A speaker should read a few ohms, not open circuit and not zero.
  • Check the high-tension fuse, if the model has one. An amplifier can have glowing heaters and a dead high-voltage rail.
  • Look at the output valves in a dark room. A valve with a bright blue or purple internal glow, or a red-hot anode, is failing and must not be run.
  • If the high-voltage rail is present at the output transformer but nothing comes out, the output transformer may have failed. This is expensive but repairable — see the transformer section of the parts page.
Continuous hum

Almost always the electrolytic filter capacitors in an amplifier of this age.

  • Hum that is present with nothing plugged in and the volume at zero points at the power supply rather than the preamp.
  • Fifty-year-old electrolytics dry out and lose capacitance. This is routine maintenance, not a fault, and replacing them is the single most worthwhile repair on an old amplifier.
  • Other causes include a failing rectifier valve, a bad earth connection on the chassis, and a heater-to-cathode short in a preamp valve. Try known-good valves first, since that costs nothing.
  • Hum that changes when you touch the instrument, or that appears only with a particular cable, is a lead or earthing problem rather than an amplifier fault.
Crackling, popping or rustling

Usually a valve, a valve socket, or a dirty potentiometer.

  • With the amplifier off and the capacitors discharged, reseat each valve in its socket. Corroded pins and loose sockets are extremely common in amplifiers that have been stored.
  • Substitute valves one at a time, starting with the preamp valves, to find the noisy one.
  • Clean the potentiometers with a proper electronic cleaner, not with household lubricant.
  • Crackling that continues after all of this can be a failing carbon-composition resistor or a bad solder joint, and it is found by careful, methodical work rather than by guessing.
The sound is weak, thin or distorted at low volume

Suspect the output valves, the bias, or the speakers.

  • Worn output valves lose emission and the amplifier becomes thin and tired. Matched replacement sets are the fix, and the bias must be set for the new valves.
  • Incorrect bias makes an amplifier sound harsh and can destroy the output valves and the transformer. Have it checked whenever output valves are replaced.
  • A speaker with a rubbing voice coil sounds distorted at low volume and cleans up as it warms, or the reverse. This is a recone job.
  • In a Portaflex, check that the speaker is the correct impedance for the amplifier and that a previous owner has not fitted something unsuitable.
The tremolo does not work

Usually the optoisolator module, in the models that use one.

  • First confirm the footswitch, if there is one, and the tremolo depth control.
  • If the tremolo has stopped altogether on a Gemini, Reverberocket or similar model, the optoisolator is the prime suspect. Replacements are available and are a drop-in fit. See the tremolo section of the parts page.
  • On models with a valve-driven tremolo, the oscillator valve is the usual culprit, and it is often a valve shared with another part of the circuit.
The reverb is weak, noisy or dead

Check the cables to the tank first, then the tank, then the drive and recovery valves.

  • The thin cables between the chassis and the reverb tank break at the connectors with remarkable regularity, particularly on amplifiers that have been moved often.
  • Check the tank's input and output windings with a meter. A tank that has been dropped can have a broken spring or a detached transducer.
  • Weak reverb is often a tired recovery valve, or a drive circuit that has drifted. On Ampegs of the mid-1960s the reverb driver is frequently a 7199.
Valves glow red, or the amplifier smells hot

Switch it off and leave it off. This is not a fault to investigate by running the amplifier.

  • A red-hot anode means the valve is being over-dissipated. Running it in that condition will destroy the valve, and may destroy the output transformer.
  • The cause is usually loss of bias, which in these amplifiers is commonly a failed bias supply, a leaky coupling capacitor or a bad valve.
  • An electrical burning smell, or a transformer that becomes too hot to touch, means stop immediately.
A valve has broken, or a valve is missing

Never substitute a valve of a different type to “see if it works”. Pin connections are not always compatible, and fitting a valve of the wrong type can destroy the amplifier. Some substitutions are legitimate and well documented — the 6L6GC in place of a 7027A in most Ampegs is the best-known example — but these are specific, researched substitutions and not guesses. Read the tube notes before fitting anything.

When to stop

Stop and take the amplifier to a technician if any of the following is true:

  • You do not have a meter rated for the voltages involved, or you do not know how to use it safely.
  • The fault is inside the high-voltage supply, the output stage or the output transformer.
  • A fuse blows more than once.
  • A valve is glowing red or the amplifier smells hot.
  • You are not certain what you are looking at.

A technician's hourly rate is far cheaper than a destroyed output transformer, and incomparably cheaper than a funeral. The answers page lists technicians who are known to understand these amplifiers.