Getting started

Tube amplifier safety

A valve amplifier can kill you while it is switched off and unplugged. Everything else on this page follows from that one fact.

The lethal detail

Ampeg amplifiers of the valve era run their internal circuitry at 400 to 700 volts DC. The large filter capacitors store that voltage, and they can hold a lethal charge for hours or even days after the amplifier is switched off and unplugged. Removing the back panel of a valve amplifier and touching the wrong thing can kill you. This is not a warning written to protect the writer; it is the single most common way people are killed working on musical equipment.

Before you open anything

  1. Decide honestly whether you should. Replacing a valve or an external fuse is a user-serviceable task. Diagnosing a hum, replacing filter capacitors, or working inside a chassis is not, unless you have been trained to do it or somebody who has is standing next to you. There is no shame in taking an amplifier to a technician, and there is a list of them on the answers page.

  2. Unplug it from the mains. Not switched off — unplugged. A switched-off amplifier with a live mains lead is still connected to the supply through the switch, and switches fail.

  3. Give it time. A valve amplifier that has just been switched off is hot enough to burn you, and its valves can shatter if they are chilled. Let it cool for at least twenty minutes before you touch anything inside.

  4. Discharge the filter capacitors. If you do not know how to do this safely, with an insulated resistor and a meter to confirm the result, stop here. Discharging capacitors by shorting them with a screwdriver is dangerous and it damages the capacitors.

  5. Verify, do not assume. Measure the high-voltage rail with a meter that is rated for the voltage, and confirm it is at a safe level before you put a hand near it. Capacitors can recharge themselves after discharge, which is why a bleeder resistor is used.

  6. One hand, always. If you must work on a live chassis, keep one hand in your pocket. Current across the chest, through the heart, is what kills. Work on an insulated surface, not a concrete floor, and never work alone.

The specific dangers in an old Ampeg

Filter capacitors
The most dangerous components in the amplifier, and the most likely to have failed after fifty years. They store the full rail voltage. A failed short-circuit capacitor can also destroy a transformer.
The mains transformer and its primary circuit
Live whenever the amplifier is plugged in, whether or not it is switched on.
Two-prong mains leads and “death caps”
Early amplifiers were often fitted with a two-conductor mains lead and a capacitor from one side of the mains to the chassis. If that capacitor fails, the chassis becomes live. This is a genuine electrocution hazard. Fitting a properly earthed three-conductor mains lead is the single most important safety modification that can be made to an old amplifier, and it is worth having done even if nothing else is touched.
Reversing the amplifier's plug
With a two-prong, unpolarised plug, reversing it can change the chassis potential. Never assume a chassis is safe to touch. Ground the chassis and use a three-prong lead.
Speaker loads
A valve amplifier must always be connected to a speaker load of the correct impedance when it is switched on. Running one with no speaker attached, or with the wrong impedance, can destroy the output transformer and the output valves. Never unplug a speaker while the amplifier is running.
Output transformers
An output transformer can generate very high voltages of its own when the amplifier is driven without a load. This is another reason not to run one without a speaker.
Hot valves and hot transformers
Output valves run at several hundred degrees. Transformers get too hot to hold. Give everything time to cool.
Physical weight
An SVT head and its cabinet, or a B-18 Portaflex, are heavy enough to injure your back. Lift with two people or a trolley, using the handles if they are sound. Age and dry wood mean old handles are not always sound.

Simple rules that prevent most accidents

Do

  • Unplug before opening
  • Let it cool down
  • Discharge and verify the capacitors
  • Use a three-conductor earthed mains lead
  • Keep a speaker load connected
  • Work with a meter, not with a finger
  • Ask for help when you are unsure

Do not

  • Assume a switched-off amplifier is safe
  • Short capacitors with a screwdriver
  • Work on a live chassis with two hands
  • Run the amplifier without a speaker
  • Fit a valve of the wrong type “just to see”
  • Replace a fuse with a higher rating
  • Work alone, or on a wet floor

On fuse ratings

Ampeg specified a 3AG slow-blow fuse of a particular rating on the back of each chassis, printed next to the holder. If a fuse blows repeatedly, there is a fault. Fitting a larger fuse or wrapping the old one in foil does not fix the fault; it transfers the damage to the transformer, which is far more expensive than a technician's time.

If somebody is electrocuted

Do not touch the person while they are in contact with the source. Switch off and unplug the supply, or use a dry, non-conductive object to separate them from it. Then call the emergency services. This paragraph is not a substitute for proper first-aid training.

Modifying an old amplifier

The earthed mains lead is the exception to the rule that vintage amplifiers should be left alone. It is a safety change, it is reversible in principle, and a competent technician can fit one without altering the sound of the amplifier. Every other modification is a trade-off against originality, and the value of an unmodified amplifier is always higher than that of a modified one. Keep the original parts.

The one modification that improves an amplifier's sound and its reliability is to have the electrolytic capacitors replaced with modern equivalents of the correct specification, which is routine maintenance rather than modification.